Voltage - Collector Emitter Breakdown (Max)
600 V
1200 V
Current - Collector (Ic) (Max)
14 A
40 A
Current - Collector Pulsed (Icm)
18 A
160 A
Vce(on) (Max) @ Vge, Ic
1.8V @ 15V, 8A
2V @ 15V, 40A
Switching Energy
310μJ (on), 3.28mJ (off)
2.61mJ (on), 1.85mJ (off)
Input Type
Standard
Standard
Td (on/off) @ 25℃
76ns/815ns
45ns/410ns
Test Condition
480V, 8A, 100Ohm, 15V
600V, 40A, 10Ohm, 15V
Reverse Recovery Time (trr)
28 ns
140 ns
Operating Temperature
-55 ℃ ~ 150 ℃ (TJ)
-55 ℃ ~ 150 ℃ (TJ)
Mounting Type
Through Hole
Through Hole
Package / Case
TO-262-3 Long Leads, I2Pak, TO-262AA
TO-247-3
Supplier Device Package
TO-262
TO-247AD